FLUKE 117C

SKU
TMMI0004
Delivery in 2 Weeks.
Pre-Order
Only 1 left

Guarantee safe & secure checkout

VoltAlert technology for non-contact voltage detection AutoVolt automatic AC/DC voltage selection Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True RMS for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30-seconds) Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak™) for hands free operation CAT III 600 V safety rated Specifications: Maximum voltage between any terminal and earth ground: 600 V Surge protection: 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display: Digital: 6, 000 counts, updates 4 per second Bar graph: 33 segments, updates 32 per second Operating Temperature: -10 °C to 50 °C Storage Temperature: -40 °C to 60 °C Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life: 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] [counts]): 0.5 % 2 DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ([% of reading] [counts]): 0.5 % 2 Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % 3 (dc, 45 Hz to 500 Hz) 4.0 % 3 (500 Hz to 1 kHz) AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz) 2.0 % 3 (500 Hz to 1 kHz) AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz) 2.0 % 3 (500 Hz to 1 kHz) Continuity Range: 600 O Resolution: 1 O Accuracy: Beeper on less than 20 O, off more than 250 O; detects opens or shorts of 500 µs or longer. Ohms Range/Resolution: 600.0 O / 0.1 O Range/Resolution: 6.000 k O / 0.001 k O Range/Resolution: 60.00 k O / 0.01 k O Range/Resolution: 600.0 k O / 0.1 k O Range/Resolution: 6.000 M O / 0.001 M O Accuracy: 0.9 % 1 Range/Resolution: 40.00 M O / 0.01 M O Accuracy: 5 % 2 Diode Test Range/Resolution: 2.000 V / 0.001 V Accuracy: 0.9 % 2 Capacitance Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 µF / 0.01 µF Range/Resolution: 100.0 µF / 0.1 µF Range/Resolution: 9999 µF / 1 µF Range/Resolution: 100 µF to 1000 µF Accuracy: 1.9 % 2 Range/Resolution: > 1000 µF Accuracy: 5% 20% LoZ capacitance Range: 1 nF to 500 µF Accuracy: 10% 2 typical AC amps true-rms (45 Hz to 500 Hz) Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.5 % 3 20 A continuous overload for 30 seconds max DC amps Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.0 % 3 20 A continuous overload for 30 seconds max Hz (V or A input) 2 Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.99 Hz / 0.1 Hz Range/Resolution: 9.999 Hz / 0.001 Hz Range/Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1 % 2  
More Information
GTIN 1,
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Stock

Shipping Method

ETA

Cost

Available

Self Pickup

1 Day

Free

Available

inside UAE

2 - 3 Days

22 AED / Free Above 50 AED

Available

International

4 - 7 Days

180 AED / 49 $

pre-order

General

2 Weeks

 

FLUKE 117C

AED 720.00