FLUKE 117C

SKU
TMMI0004
Brand
In stock
Only 16 left
Add to Wish List

Guarantee safe & secure checkout

VoltAlert technology for non-contact voltage detection AutoVolt automatic AC/DC voltage selection Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True RMS for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30-seconds) Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak™) for hands free operation CAT III 600 V safety rated Specifications: Maximum voltage between any terminal and earth ground: 600 V Surge protection: 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display: Digital: 6, 000 counts, updates 4 per second Bar graph: 33 segments, updates 32 per second Operating Temperature: -10 °C to 50 °C Storage Temperature: -40 °C to 60 °C Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life: 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] [counts]): 0.5 % 2 DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ([% of reading] [counts]): 0.5 % 2 Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % 3 (dc, 45 Hz to 500 Hz) 4.0 % 3 (500 Hz to 1 kHz) AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz) 2.0 % 3 (500 Hz to 1 kHz) AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz) 2.0 % 3 (500 Hz to 1 kHz) Continuity Range: 600 O Resolution: 1 O Accuracy: Beeper on less than 20 O, off more than 250 O; detects opens or shorts of 500 µs or longer. Ohms Range/Resolution: 600.0 O / 0.1 O Range/Resolution: 6.000 k O / 0.001 k O Range/Resolution: 60.00 k O / 0.01 k O Range/Resolution: 600.0 k O / 0.1 k O Range/Resolution: 6.000 M O / 0.001 M O Accuracy: 0.9 % 1 Range/Resolution: 40.00 M O / 0.01 M O Accuracy: 5 % 2 Diode Test Range/Resolution: 2.000 V / 0.001 V Accuracy: 0.9 % 2 Capacitance Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 µF / 0.01 µF Range/Resolution: 100.0 µF / 0.1 µF Range/Resolution: 9999 µF / 1 µF Range/Resolution: 100 µF to 1000 µF Accuracy: 1.9 % 2 Range/Resolution: > 1000 µF Accuracy: 5% 20% LoZ capacitance Range: 1 nF to 500 µF Accuracy: 10% 2 typical AC amps true-rms (45 Hz to 500 Hz) Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.5 % 3 20 A continuous overload for 30 seconds max DC amps Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.0 % 3 20 A continuous overload for 30 seconds max Hz (V or A input) 2 Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.99 Hz / 0.1 Hz Range/Resolution: 9.999 Hz / 0.001 Hz Range/Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1 % 2  
More Information
Brand Fluke
GTIN 1,
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Stock

Shipping Method

ETA

Cost

Available

Self Pickup

1 Day

Free

Available

inside UAE

2 - 3 Days

22 AED / Free Above 50 AED

Available

International

4 - 7 Days

180 AED / 49 $

pre-order

General

2 Weeks

 

FLUKE 117C

AED 720.00